Running a generator on gas instead of petrol changes more than the bottle you plug into it. Output shifts, runtime is measured differently, and the kit at the back of the machine changes. For Australian campers, caravanners, and anyone building a home backup plan, understanding those trade-offs before you buy saves money later. This guide explains what genuinely changes when you switch fuels, from power and cylinder runtime to fittings, cold-weather starting, and servicing.

Petrol, LPG, and Dual-Fuel Generators Explained

A dual-fuel generator runs on two fuels, usually petrol and LPG, with a switch or valve to select which one feeds the engine. An LPG generator runs on liquefied petroleum gas alone, drawn from a refillable cylinder. A petrol generator runs on unleaded fuel from an onboard tank. The engines are broadly similar. The real difference sits in how the fuel is stored, delivered, and burned.

How Each Fuel Behaves

Petrol is energy-dense and easy to carry in a jerry can, which is why it remains the default for portable generator units. LPG, most often propane in Australia, burns cleaner and can be stored indefinitely in a sealed cylinder without going stale. Dual-fuel gives you both options in one chassis, so you can run on whatever is cheaper or handier on the day.

What Dual-Fuel and Multi-Fuel Really Mean

Marketing language varies, so read the specification sheet rather than the headline. Dual-fuel almost always means petrol and LPG. A multi-fuel generator may add a third option such as natural gas from a mains connection, which suits fixed home backup more than camping. The fittings and regulators differ between them, so the label matters.

Who Each Option Suits

Petrol suits short bursts and infrequent use where portability matters most.

LPG suits long steady runs, standby duty, and users who dislike storing petrol.

Dual-fuel suits people who want flexibility and a fallback if one fuel runs out.

Inverter models, which produce clean pure sine wave power safe for laptops and phones, are available across all three setups. Outbax stocks a broad range of portable generators for these use cases.

Gentrax GT2200 Pro Inverter Generator

Gentrax GT2200 Pro Inverter Generator

How Much Power You Lose Running on LPG

Here is the change most buyers notice first. A generator running on LPG typically produces slightly less power than the same engine running on petrol, often in the region of 10 per cent less as a rough guide. The exact figure depends on the engine, the regulator, and the load, so plan for a modest reduction rather than identical output.

Why the Output Difference on Gas Happens

LPG delivers less energy to the combustion chamber per cycle than petrol under the conditions these engines run, so peak output eases back. It is not a fault. It is simply how the two fuels compare. In practice, a unit rated at 3.5kW on petrol may deliver slightly less on gas.

Runtime and Fuel Efficiency

Runtime on gas is governed by cylinder size rather than a small onboard tank, which is often an advantage. A larger cylinder can keep a generator running far longer between refills than a petrol tank allows. Fuel efficiency depends on load, so a lightly loaded machine sips gas while a heavily loaded one drinks it.

Matching Wattage to Your Load

Add up everything you need to run at once, then leave headroom. If the LPG reduction pushes you close to the limit, size up so the generator is comfortable rather than straining. The Gentrax 3.5kW Silent Inverter Generator (GT3500) suits camping and small caravan loads, while the Outbax Gentrax 7.7kW Max 7.0kW Inverter Generator is built for heavier home backup demand where that headroom counts.

Here’s what one of our customers said about Gentrax GT3500 Inverter Generator:

“This is the second Gentrax we have bought. The first one is for myself and I purchased the second for my boss. Last summer we lost power for 4 days and it worked perfectly allowing us to use lights, fans and keeping two fridges going. I highly recommend having an electrician install a power point and change over switch in power box. We were also able to supply our two elderly neighbors with an extension lead to keep their fridges working.”

LPG Cylinders: Size, Runtime, Storage, and Transport

Cylinder choice shapes how long you run and how easily you move. In Australia, the familiar 9kg bottle, the same swap-and-go size used for barbecues, is the common portable choice. Larger 45kg cylinders suit fixed home backup where you want long unattended runtime.

VoltX VX6600 2-Wire Inverter Generator

VoltX VX6600 2-Wire Inverter Generator

Cylinder Size and Duration

A 9kg cylinder holds a useful amount of gas, and at light to moderate load a mid-sized generator can run for several hours on one. Increase the load, and that time shortens. For extended off-grid stays or overnight backup, a larger cylinder or a spare bottle removes the worry.

Estimating LPG Cylinder Runtime

Runtime depends on load, so treat any single figure with caution. As a working method, note your generator gas consumption rate from the manual, then divide the cylinder usable gas by that rate. Running at quarter to half load stretches a bottle much further than running flat out. Keeping a spare is the simplest insurance.

Storing and Transporting Cylinders Safely

Store cylinders upright, in a ventilated space, away from heat and ignition sources, and never inside a sealed hot car for long periods. Transport them secured and upright, and observe the quantity limits that apply to gas in vehicles. Always run the generator outdoors in open air, because every fuel-burning generator produces carbon monoxide, which is deadly in enclosed spaces.

Fittings, Regulators, and Cold Weather Starting

Switching to gas means swapping the hardware at the back of the machine, and this is where buyers most often get caught out. It pays to get it right before the trip.

Gentrax GS2-5000IE 4.5kW Portable Inverter Generator

Gentrax GS2-5000IE 4.5kW Portable Inverter Generator

Regulator and Hose Fittings You Need

An LPG generator needs a correctly rated regulator to step cylinder pressure down to the level the engine expects, plus a compatible hose and fitting. In Australia, that usually means a POL or Type 21 connection at the bottle. Use the regulator and hose specified for your unit rather than improvising, and check the seals for leaks with soapy water before starting. If you still smell gas, stop and investigate.

Dual Fuel Conversion and Switching Over

Factory dual-fuel machines make switching simple, often with a valve or dial you turn with the engine off. Some petrol generators can be converted with a dedicated kit, but this should follow the manufacturer’s guidance. When in doubt, buy a purpose-built dual-fuel unit rather than modifying a petrol-only one.

Cold Weather Performance

Propane actually performs well in the cold, staying usable at temperatures far below anything most Australians will camp in. The practical limit isn’t the fuel freezing, but the rate at which a small cylinder can vaporise gas under heavy draw, which slows as a bottle nears empty in genuinely cold conditions. Petrol has its own cold start quirks. For alpine trips, a fuller cylinder and a sensible load keep things reliable.

Servicing, Running Costs, and Choosing the Right Generator

Gas changes the maintenance picture, mostly for the better, but it is not maintenance-free.

Servicing Differences

LPG burns cleaner than petrol, so combustion leaves less carbon behind, and engine oil tends to stay cleaner for longer. Gas also never goes stale, a real benefit for standby machines that sit for months, because there is no varnished petrol to gum up a carburettor. You still service the engine, oil, air filter, and spark plug on schedule. Dual-fuel adds the gas train, regulator, hose, and seals to your inspection list.

Running Costs and When Dual-Fuel Pays Off

Compare the cost of a cylinder refill against a tank of petrol for the runtime you actually get. Gas often works out competitively, and the convenience of swap-and-go bottles has its own value. Dual-fuel earns its place when you want flexibility and a fallback, rather than committing to a single fuel supply.

Picking a Unit for Camping, Caravan, or Off-Grid Power

For quiet camping and caravan trips, a compact inverter unit is usually the sweet spot. The Outbax Gentrax GTX4200 Pro Inverter Generator is aimed squarely at camping and RV use, while the Gentrax GTX3500 Inverter Generator with remote electric start adds convenience for caravanners who would rather not pull a cord. Browse the full Outbax portable generators and inverter generators ranges to compare noise, wattage, and start type side by side.

Here’s what one of our customers said about the Gentrax GTX4200 Pro Inverter Generator:

“Fantastic product especially if you are a woman who just needs the basics. This is a top quality easy to operate machine. And it’s pretty. I love how it looks.”

Kuller 4200 Inverter Generator

Kuller 4200 Inverter Generator

Choosing the Fuel Setup That Fits Your Power Needs

The trade-offs are straightforward once you see them clearly. Gas costs you a small amount of output but rewards you with clean storage, long runtime, and easy cold starting, while petrol keeps things simple and portable. Dual-fuel gives you the freedom to switch. Work out how you use power, whether that is weekend camping, caravan touring, or home backup, then match the fuel and the wattage to that. When you are ready to compare units, the Outbax portable generator range is a sensible place to weigh noise, output, and start type against your needs.

Frequently Asked Questions

  • How much power do you lose running a generator on LPG?

    Expect a modest reduction, often around 10 per cent compared with petrol, though the exact figure varies by engine and load. Size your generator properly with that headroom in mind so it is not straining on gas.

  • How long will a 9kg gas bottle run my generator?

    It depends entirely on load. At light to moderate demand, a mid-sized generator can run for several hours on a single 9kg cylinder, but heavy loads shorten that considerably. Check your gas consumption rate in the manual and keep a spare bottle.

  • What regulator and hose do I need to run a generator on gas?

    You need a regulator rated for your unit and a compatible hose, usually with a POL or Type 21 fitting at the cylinder in Australia. Use the parts specified by the manufacturer, and leak-test the connection with soapy water before every start.

  • Can I store and transport LPG cylinders in my car or caravan?

    Yes, within the limits that apply to gas in vehicles. Keep cylinders upright, secured, and ventilated, and never leave them in a sealed hot car for long periods or store them near ignition sources.

  • Do LPG generators start reliably in cold weather?

    Propane handles the cold well, staying usable far below normal Australian camping temperatures. The main constraint is vaporisation rate under heavy draw from a nearly empty cylinder in genuinely cold conditions, so start alpine trips with a fuller bottle.

  • Is a dual fuel-generator worth it over a petrol-only model?

    If you value flexibility and a fuel fallback, yes. Dual-fuel lets you run on whichever fuel is cheaper or handier and keeps you going if one supply runs out. If you only ever use petrol, a dedicated petrol unit is simpler.

  • Does running on gas need different servicing?

    Gas burns cleaner, so carbon build-up and oil contamination are reduced, and there is no stale fuel to clog a carburettor. You still service the engine on schedule, and a dual-fuel machine adds the regulator, hose, and seals to your checks.

  • Are LPG or dual fuel generators good for home backup?

    They can be excellent. Gas stores indefinitely, so a standby unit is always ready, and a large cylinder gives long unattended runtime. Choose a higher-output model with headroom for all your home needs.

  • Can I convert my petrol generator to run on LPG?

    Some models can be converted with a dedicated kit, but only where the manufacturer allows it and ideally with professional fitting. For most buyers, a purpose-built dual-fuel unit is safer and simpler.

  • Is LPG cheaper than petrol for running a generator?

    It is often competitive, and swap-and-go bottles add convenience, but the real cost depends on your load and local prices. For a fair comparison, compare the runtime you get from a cylinder refill with a tank of petrol.